Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tribol Lett ; 70(1): 24, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35210723

RESUMO

Soot is the main contamination that affects oil performance and increases the frequency of oil changes in heavy-duty engine oil. Several studies discussed that additive concentration in engine oil can be influenced due to additive depletion over time and additive adsorption on soot particles. To extend oil drain intervals and improve oil performance, filter manufactures explore removing the soot to a certain level and replenishing the consumed additives. Zinc dialkyl dithiophosphate (ZDDP) is one of the most favored antiwear additives that react very rapidly with rubbing surfaces to form tribofilm that reduces wear. In this study, the experimental work aims to investigate the effect of ZDDP replenishment on tribological performance in the existence of soot and after removing soot from heavy-duty used oil. The study reveals that reclaiming the used oil can be achieved by removing the soot to a certain level. The results demonstrate that the reclaimed oil after removing soot is still not as good as the fresh oil. This study proves that additive depletion, additive adsorption on soot, and the decomposition of antiwear additive adversely influence the reclaimed oil performance. However, replenishing the consumed additive by adding a small amount of ZDDP helps to improve the reclaimed oil performance compared to a large amount of ZDDP which is required to re-gain the oil performance in the existence of soot.

2.
Rev Sci Instrum ; 88(1): 015101, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147643

RESUMO

The complex tribochemical nature of lubricated tribological contacts is inaccessible in real time without altering their initial state. To overcome this issue, a new design of a pin-on-disc tribological apparatus was developed and combined with synchrotron X-ray absorption spectroscopy (XAS). Using the designed apparatus, it is possible to study in situ the transient decomposition reactions of various oil additives on different surfaces under a wide range of realistic operating conditions of contact pressure (1.0-3.0 GPa), temperature (25-120 °C), and sliding speed (30-3000 rpm or 0.15-15 m/s). To test the apparatus, several tribological tests were performed at different shearing times ranging from 2.5 to 60 min. These tests were carried out under helium atmosphere at a temperature of 80 °C, contact pressure of 2.2 GPa, and sliding speed of 50 rpm. The XAS experiments indicate that the zinc dialkyldithiophosphate antiwear additive decomposes in the oil to form a tribofilm on the iron surface at different reaction kinetics from the ones of the thermal film. The tribofilm composition evolves much faster than the one of the thermal film, which confirms that the formation of the tribofilm is a thermally activated process similar to the one of the thermal film but accelerated by shear. Furthermore, the results indicate that the sulfur of the formed film, whether a tribofilm or a thermal film, appears initially in the form of sulfate, with some sulfide, which under heat or shear is reduced into mainly sulfide.

3.
Eur J Trauma Emerg Surg ; 43(4): 497-504, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27194249

RESUMO

PURPOSE: Scar formation after injured peripheral nerve repair is a significant clinical problem because it prevents nerve regeneration. The aim of this study was to investigate and compare the effects of hyaluronic acid (HA) and tacrolimus (FK506) on peripheral nerve regeneration in rabbits after the drugs were topically applied at the site of nerve repair. METHODS: Thirty adult male European rabbits (Oryctolagus cuniculus), ranging in weight from 2.5 to 3 kg, were randomly assigned to three groups: the HA and FK506 groups comprised the experimental groups, while the saline group served as the control. At week 12, macroscopic and microscopic evaluations were performed and analyzed. RESULTS: In general, the macroscopic evaluations (skin and muscle fascia closure and nerve adherence), microscopic evaluations (cellular components, scar tissue formation index, and histomorphological organization), and measurements of nerve diameter and gastrocnemius muscle wet weight demonstrated the positive effects of topical application of these pharmacological agents (HA and FK506); HA and FK506 prevented scar formation and enhanced nerve regeneration. No significant differences in the parameters described above were observed between the HA and FK506 groups (P > 0.05). However, significant differences were observed between both the HA and FK506 groups and the saline group (P < 0.05). CONCLUSION: Based on our findings, topical application of HA and FK506 exhibits equally positive effects, preventing perineural scar formation and enhancing nerve regeneration after peripheral nerve repair.


Assuntos
Cicatriz/prevenção & controle , Ácido Hialurônico/farmacologia , Regeneração Nervosa/efeitos dos fármacos , Nervo Isquiático/lesões , Tacrolimo/farmacologia , Administração Tópica , Animais , Ácido Hialurônico/administração & dosagem , Masculino , Modelos Animais , Coelhos , Tacrolimo/administração & dosagem
4.
Acta Biomater ; 7(11): 4007-17, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21757033

RESUMO

Bio-inspired microstructured surfaces have been developed that attach effectively to a wet surface. However, little is known about the associated tribological and adhesion properties involved. In this paper, the adhesion of a microstructured surface to peritoneal tissue is investigated as a function of preload, speeds of approach and angle of tilt to the horizontal. Results show that within a critical range of preload and speed of approach of the microstructured surface to the tissue result in good adhesion characteristics at the micro-structured surface/tissue interface. The microstructured surface adhesion to the tissue and the payload supported against gravity depend significantly on the tilt angle to the horizontal. Furthermore, a wet adhesion model was used to elucidate the adhesion mechanism of the microstructured surface to a wetted glass. These tests provide significant initial data for the design of a miniature mobile intra-abdominal device which drives the need for this adhesion study.


Assuntos
Parede Abdominal , Peritônio , Adesividade , Animais , Humanos , Ratos , Molhabilidade
5.
Br J Neurosurg ; 1(2): 251-9, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3267289

RESUMO

A series of 11 patients with a basilar tip aneurysm were treated operatively. The aneurysm had ruptured in all cases and caused at least one haemorrhage prior to surgery. Four patients harboured large aneurysms, while in the rest of them the aneurysms were small in size. In all the 11 patients a modified pterional transcavernous-transsellar approach was used which considerably facilitated clipping and secured complete exclusion of all aneurysms, including the large ones. Eight patients made a complete recovery and resumed their original occupation. One is hemiparetic but capable of self care, one is hemiplegic, and one died after surgery. The purpose of this report is to present our modified surgical approach to basilar tip aneurysms, which provides good exposure of the entire region of the bifurcation of the basilar artery and adjacent blood vessels as far as the anterior inferior cerebellar arteries, and requires but minimal retraction of the brain.


Assuntos
Aneurisma Intracraniano/cirurgia , Neurocirurgia/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...